Aluminium Conductor Power Cable

Aluminium Conductor Power Cable

Conductor type: AAC AAAC ACSR ACAR ACSS/TW ABC
Application:Overhead
Jacket:No sheath, Without
Product name:ACSR Cable
Conductor:Aluminium Conductor Steel Reinforced
Color:Silver white
Standard:GB1179, IEC 1089, DIN 48204, ASTM B232, BS215
Send Inquiry
Description
modular-1
Aluminium Conductor Power Cable - Reliable and Cost-Effective Power Transmission Solution

Products Description

Aluminium Conductor Power Cable is one of JSH Cable's best-selling products. We manufacture aluminum conductor cables in various specifications including AAC, AAAC, ACSR, ACAR, ACSS/TW and ABC, all produced with advanced extrusion technology to ensure stable and reliable quality. With excellent conductivity and cost advantages, our aluminum core cables are widely used in power transmission, industrial distribution and infrastructure construction. We maintain large ready stock to quickly meet various project requirements.

power cable
 
Construction
 

1.Conductor (both phase and Neutral)
The conductors shall be of aluminum 1350 wires and compacted circular stranded ;
2.Insulation:
The conductors shall be extruded with XLPE as insulation ,each phases is marked with numbers and letters ,

ONE,TWO,THREE or with one rib,two ribs or three ribs to denote the phases.The neutral core carries equally space ribs right round the circumference
3.Assembly
The Core shall be laid up with a left hand Lay.

Specifications

Type

Description

AAC All Aluminum Conductor
ACSR Aluminum Conductor Steel Reinforced
AAAC All aluminum Alloy Conductor
ACAR Aluminum Conductor Alloy Reinforced
AACSR All Aluminum Alloy Conductor Steel Reinforced
ACSR/AW Aluminum Conductor Aluminum Clad Steel Reinforced
TACSR Thermal Resistant Aluminum-alloy Conductor Steel Reinforced
ACSS Aluminum Conductor Steel Supported
ACSS/AW Aluminum Conductor. Aluminum-Clad Steel Supported
ACSS/TS Aluminum Conductor, Steel Supported. Trapezoidal Shaped
ACS Aluminum Clad Steel
CCS Copper Clad Steel
GSW Galvanized Steel Wire
BCC Bare copper stranded conductor (Hard Drawn)
Greased conductor Anti-corrosive stranded conductor

power cable

CONSTRUCTION OF OVERHEAD CONDUCTORS

power cable

Products Parameter

The technical data of Aluminium Conductor AAC AAAC ACSR ACAR ACSS/TW ABC Power cable power wire astm b232 acsr overhead conductor as below for reference,any customized is available.

Code Name Nominal
aluminu
m area
mm2
Stranding structure Sectional
area of
aluminum
Total
sectional
area
Overall
diameter
Total Calculated
breaking
load
Calculate D.C
resistance at20℃
AI.No. AI.Dia. St.No. St.Dia. mm2 mm2 mm Kg/Km daN Ω/Km
Mole 10 6 1.5 1 1.5 10.62 12.39 4.5 43 414 2.706
Squirrel 20 6 2.11 1 2.11 20.94 24.43 6.33 85 788 1.368
Gopher 25 6 2.36 1 2.36 26.24 30.62 7.08 106 961 1.093
Weasel 30 6 2.59 1 2.59 31.61 36.88 1.77 128 1146 0.9077
Fox 35 6 2.79 1 2.79 36.66 42.77 8.37 149 1320 0.7822
Ferret 40 6 3 1 3 42.41 49.48 9 172 1520 0.6766
Rabbit 50 6 3.35 1 3.35 52.88 61.7 10.05 214 1835 0.5426
Mink 60 6 3.66 1 3.66 63.18 73.71 10.98 255 2180 0.4545
Skunk 60 12 2.59 7 2.59 63.27 100.3 12.95 465 5300 0.4567
Beaver 70 6 3.99 1 3.99 74.82 87.29 11.97 302 2570 0.3825
Horse 70 12 2.79 7 2.79 73.37 116.2 13.95 538 6120 0.3936
Racoon 75 6 4.1 1 4.1 79.2 92.4 12.3 320 2720 0.3622
IEC 61089Standard
Code
number
Area Number of
wires
Wire dia. Diameter Linear
Mass
Rated
Strength
D.C.
Resistanc
Alum. Steel Total Alum. Steel Core Con
mm2 mm2 mm2 AI St mm mm mm mm Kg/Km kN Ω/Km
16 16 2.67 18.7 6 1 1.84 1.84 1.84 5.53 64.6 6.83 1.7934
25 25 4.17 29.2 6 1 2.3 2.3 2.3 6.91 100.9 10.25 1.1478
40 40 6.67 46.7 6 1 2.91 2.91 2.91 8.74 161.5 16.2 0.7174
63 63 10.5 73.5 6 1 3.66 3.66 3.66 11 254.4 24.15 0.4555
100 100 16.7 117 6 1 4.61 4.61 4.61 13.8 403.8 38 33 0.2869
125 125 6.94 132 18 1 2.97 2.97 2.97 14.9 397.9 31.04 0.2304
125 125 20.4 145 26 7 2.47 2.47 2.47 15.7 503.9 51.39 0.231
160 160 8.89 169 18 1 3.36 3.36 3.36 16.8 509.3 38.67 0.18
160 160 26.1 186 26 7 2.8 2.8 2.8 17.7 644.9 64.99 0.1805
200 200 11.1 211 18 1 3.76 3.76 3.76 18.8 636.7 46.89 0.144

Application

AAC AAAC ACSR Aluminum Power cable as a new-type aerial cable is used for transmitting electric power overhead,
extensively used in rebuilding of urban and forest region electrified wire nttting.
It improves the safety and reliance of electrified wire netting.

 

AAC AAAC ACSR Aluminum Power cable
Applications of bare
conductor
To supply 120 volt aerial service for temporary service at construction sites,outdoor or streetighting . For service at 600volts or lower at a conductor temperature of 75°C maximum.
Applications of bare conductor To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt orless (phase to phase) at a
conductor temperature of 75°C maximum for polyethylene insulation 90'C maximum for crosslinkedinsulation.
Applications of bare conductor Used to supply 3 phase power, usually from a polemounted transformer, to the user's service headwhere connection to the service
entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductoitemperatures not to exceed
75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulatedconductors

 

Hot Tags: aluminium conductor power cable, China aluminium conductor power cable manufacturers, suppliers, factory, aerial cable, Aluminium Conductor Power Cable, Aluminum Insulated Overhead Cable